Sign In | Join Free | My fnxradio.com |
|
Brand Name : PHiliph
Model Number : 989803144531
MOQ : 1
Payment Terms : T/T, Western Union,PayPal
Delivery Time : 3-5 working days
Product name : PHiliph
Type : CO2 Airway Adapter Set
Application : medical equipment,ICU,hospital device,defibrillator
Warranty : 90days
PN : 989803144531
Product situation : In Good Order
Mode of transport : Expressage
Product Type : SpO2 Cable
Package Weight : 0.320 kg
Single-Patient Use OR Multi-Patient Use : Single-Patient Use
Packaging Unit : 10 per case
Minimum Shelf Life : None
Sterile OR Non-Sterile : Non-Sterile
Technology : Sidestream
Tube Length : 2.5 m (8'4")
With Oxygen : No
PHiliphhilip CO2 Airway Adapter Set 989803144531 (ET tube ≤ 4.0 mm) CapnograPHiliphhilipy, Sidestream
► Brief Introduction
PHiliphhilip CO2 Airway Adapter Set 989803144531 is All-in-one single patient use airway adapter kits for long- and short-term etCO2 monitoring of intubated adult, pediatric and infant patients. It's work for short term Up to 12 hours (patient non-humidified). It's usually applications at Operating room, recovery room.
CapnograPHiliphhilipy, which is also referred to as end tidal carbon dioxide (etCO2) monitoring, is a non-invasive measure of the inspired and expired carbon-dioxide concentration. It provides a graPHiliphhilipical and numerical display of the partial pressure of carbon dioxide within the patients' airway. A detailed analysis of the waveform (capnogram) can reveal to the clinician both complex and subtle changes of the patients ventilatory status.
► Monitoring efficiency of mechanical ventilatory support
Patients who are intubated and receiving mechanical ventilatory support benefit from etCO2 monitoring in several ways;
► Performance:
Product # | Description | Use With: |
989803144531 | Airway Adapter Set - ET <=4.0mm | M2741A Sidestream Sensor with Sidestream Ext. Server: M3014A. Monitors: MP5: M8105A, MP2: M8102A, MMS X2: M3002A, 860335, 860338 |
► What is the limitation of sidestream for intubated patients?
Patients who require intubation and long term ventilation typically will have thick secretions that are expelled through coughing or by suctioning. Because sidestream technology requires that the gas sample be transported from the breathing circuit, through the sample line to reach the CO2 analyzer, these secretions often will be aspirated into the sample line, causing the line to occlude requiring user intervention to correct the situation.
Thank you for your time and interest in PHiliphhilip CO2 Airway Adapter Set 989803144531 (ET tube ≤ 4.0 mm) CapnograPHiliphhilipy, Sidestream, "Quality assurance" is our eternal pursuit and promise. Don't be hesitant to contact us! Welcome to place your orders.
![]() |
PHiliph CO2 Airway Adapter Set 989803144531 ET Tube 4.0 Mm CapnograPHiliphy Sidestream Images |