Mindray MPM Module SpO2 Board 050-000046-00 051-000058 For MPM Module

Brand Name : Mindray

Model Number : 050-000046-00 051-000058

MOQ : 1

Payment Terms : T/T, Western Union,PayPal

Delivery Time : 3-5 working days

Product name : Mindray

Type : 050-000046-00 051-000058

Application : medical equipment,ICU,hospital device

Warranty : 90days

Product superiority : Original

Product conditions : In Good working Condition

Nominal Voltage : 110V—240v

Index Terms : T4000F PRO Multi-parameter Patient Monitor

Material : Plastic, PCB, etc

Operation policy : Advanced technology, high-quality products, attentive service

Post-sales service : Passion in serving our customer with the best service

Features Introduction : Practical,Economic,Durable

Stock : On sale

Contact Now

Mindray MPM Module SpO2 Board 050-000046-00 051-000058

► Brief Introduction

The monitor uses the oscillometric method to measure non-invasive blood pressure (NIBP). NIBP measurement is based on the principle that pulsating blood flow in an artery causes oscillations in the arterial wall. Oscillometric devices use a blood pressure cuff to sense these oscillations, which appear as tiny pulsations in the cuff pressure. Oscillometric methods measure mean pressure and determine systolic and diastolic pressures. Oscillometric devices measure the amplitude of the pressure change in the occlusive cuff as the cuff is deflated from above the systolic pressure. When the pulse breaks through the arterial occlusion, the amplitude suddenly increases. As the cuff pressure is further reduced, the pulsation amplitude increases, reaches a maximum value (close to the mean pressure), and then decreases.

Measurement Modes

There are three NIBP measurement modes:

  • Manual: measurement on demand.
  • Auto: repeated measurements at set interval.
  • STAT: continually rapid series of measurements over a five minute period.
  • Sequence: continually automatic measurement at set durations and intervals.

► Warning

• Be sure to select the correct patient category setting for your patient before NIBP measurement. Do not apply the higher adult settings for pediatric or neonatal patients. Otherwise, it may present a safety hazard.

• Do not measure NIBP on patients with sickle-cell disease or on the limb where skin damage has occurred or is expected.

• Use clinical judgment to determine whether to perform frequent unattended blood pressure measurements on patients with severe blood clotting disorders because of the risk of hematoma in the limb fitted with the cuff.

• Do not use the NIBP cuff on a limb with an intravenous infusion or arterial catheter in place. This could cause tissue damage around the catheter when the infusion is slowed or blocked during cuff inflation.

• Do not apply cuff on the arm on the side of a mastectomy.

• Continuous cuff pressure due to connection tubing kinking may cause blood flow interference, and resulting in harmful injury to the patient.

• NIBP reading can be affected by the measurement site, the position of the patient, exercise, or the patient's physiologic condition. If you doubt the NIBP measurements, determine the patient’s vital signs by alternative means, and then verify that the monitor is working correctly.

• Devices that exert pressure on tissue have been associated with purpura, ischemia, and neuropathy. Inspect the application site regularly to ensure skin quality and inspect the extremity of the cuffed limb for normal color, warmth and sensitivity. If the skin quality changes, or if the extremity circulation is being affected, move the cuff to another site or stop the blood pressure measurements immediately. Check more frequently when making automatic or STAT measurements. Auto NIBP measurements with one and two minute intervals are not recommended for extended periods of time.

• NIBP diagnostic significance must be decided by the physician.

► Specification

Item Default Setting
TXX
(XX refers to temperature site)
Alarm switch On
High limit 38.0 °C
Low limit 35.0 °C
Priority Med
Alarm Outputs Off
ΔT Alarm switch On
High limit 2.0 °C
Priority Med
Alarm Outputs Off

Mindray MPM Module SpO2 Board 050-000046-00 051-000058 For MPM Module

Thank you for your time and interest in Mindray MPM Module SpO2 Board 050-000046-00 051-000058 .

If you want to explore more details please let us know. Any inquiry will be highly appreciated and thanks for your support. Looking forward to receiving your early inquiry.


Product Tags:

051-000058 SpO2 Board

      

MPM Module SpO2 Board

      

050-000046-00 SpO2 Board

      
Wholesale Mindray MPM Module SpO2 Board 050-000046-00 051-000058 For MPM Module from china suppliers

Mindray MPM Module SpO2 Board 050-000046-00 051-000058 For MPM Module Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: China World Technology Medical Equipment Service Group
*Subject:
*Message:
Characters Remaining: (0/3000)