Sign In | Join Free | My fnxradio.com
China China World Technology Medical Equipment Service Group logo
China World Technology Medical Equipment Service Group
China World Technology Medical Equipment Service Group Win-win together!
Verified Supplier

5 Years

Home > Patient Monitor Accessories >

0152-30-39689 Mindray TEL-100 Telemetry Spo2 Module With Extension Cable

China World Technology Medical Equipment Service Group
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

0152-30-39689 Mindray TEL-100 Telemetry Spo2 Module With Extension Cable

Brand Name : Mindray

Model Number : 0152-30-39689

MOQ : 1pcs

Payment Terms : T/T(wire transfer), Western Union, Paypal

Delivery Time : 3-5 working days

Packaging Details : Carton

Product Name : 0152-30-39689 Mindray TEL-100 Telemetry Spo2 Module With Extension Cable

Brand : Mindray

Part No : 0152-30-39689

use for : Mindray TEL-100 Telemetry

SpO2 range : 0 to100%

Pulse rate range : 20 to 300 bpm

Wavelength : Red light to 660 nm Ultra-red light to 910 nm

SpO2 accuracy (±1 SD) : 70 to 100% ± 2 bpm (finger sensor, adult) 70 to 100% ± 4 bpm (ear sensor) <70% not defined (all sensors)

Pulse accuracy : ±3% ±1 bpm

MOQ : One piece

Contact Now

0152-30-39689 Mindray TEL-100 Telemetry Spo2 Module With Extension Cable

SpO2 measurement principle

SpO2 monitoring is a non-invasive method of measuring the amount of oxygenated hemoglobin and heart rate by measuring the absorption of light at selected wavelengths. The light generated by the probe passes through the tissue and is converted into an electrical signal by the probe's photodetector. The SpO2 module processes the electrical signals and displays a digital value of SpO2 and heart rate on the screen.

After positioning the sensor, connect the sensor to the SpO2 module and then connect the module to the SpO2 connector on the transmitter. Don't forget to connect the SpO2 extension cable. Make sure cables are not tangled and away from ESUs or other electrical equipment. The ECG cable acts as the transmitter's antenna. Even if you are not interested in monitoring the ECG progress, don't forget to connect it to the transmitter.

Note

  • Place the SpO2 sensor cable on the back of the patient's hand. Make sure the nail is pointing directly at the sensor light.

  • Inaccurate SpO2 readings can occur if the sensor is not properly placed in the measurement position or if the system is unable to detect a pulse and is unable to measure SpO2. In this case, the sensor must be moved.

  • Excessive patient movement may cause inaccurate readings. In this case, the patient should be immobilized or the application area of the sensor changed to minimize distractions from excessive movement.

  • The transmission wire uses the shielding layer as a transmitting antenna. Therefore, if the ECG leads are correctly connected during blood oxygen monitoring, the RF signal will be transmitted correctly. Otherwise, communication is disabled.

SpO2 Specifications

SpO2 range 0 to100%
Pulse rate range 20 to 300 bpm
Wavelength Red light to 660 nm Ultra-red light to 910 nm
SpO2 accuracy (±1 SD) 70 to 100% ± 2 bpm (finger sensor, adult) 70 to 100% ± 4 bpm (ear sensor) <70% not defined (all sensors)
Pulse accuracy ±3% ±1 bpm

Export

CWT Technology HK Limited has a long history of exporting used medical equipment all over the world.

We have customers in many countries, including America, Europe and Colombia, Mexico, Chile, Saudi Arabia, UAE, Southeast Asia, etc.

When you buy from us, you can rest assured that your item will be properly packed and all documents will be prepared according to your instructions. We have excellent relationships with local shipping lines/forwarders and we are able to handle any type of shipping required.

0152-30-39689 Mindray TEL-100 Telemetry Spo2 Module With Extension Cable

Thank you so much for your attention .If you're interested in 0152-30-39689 Mindray TEL-100 Telemetry Spo2 Module With Extension Cable ,feel free to contact us .Thank you .


Product Tags:

Mindray TEL-100 Telemetry Spo2 Module

      

0152-30-39689 Telemetry Spo2 Module

      
Wholesale 0152-30-39689 Mindray TEL-100 Telemetry Spo2 Module With Extension Cable from china suppliers

0152-30-39689 Mindray TEL-100 Telemetry Spo2 Module With Extension Cable Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: China World Technology Medical Equipment Service Group
*Subject:
*Message:
Characters Remaining: (0/3000)